© 2023 Enphase Energy. All rights reserved. Enphase, the e and CC logos, IQ, and certain other marks listed at https://enphase.com/trademark-usage-guidelines are trademarks of Enphase Energy, Inc. in the US and other countries. Data subject to change.IQB-5P-DSH-00010-4.0-EN-US-2023-11-07IQ Battery 5PThe IQ Battery 5P all-in-one AC-coupled system is powerful, reliable, simple, and safe. It has a total usable energy capacity of 5.0 kWh and includes six embedded grid-forming microinverters with a 3.84 kVA continuous power rating. It provides backup capability, and installers can quickly design the right system size to meet the customer needs.Powerful• Provides 3.84 kVA continuous and 7.68 kVA peak power• Doubles the available power per kWh of prior generations of IQ Battery• Includes six embedded IQ8D-BAT MicroinvertersReliable• 15 years limited warranty• Cools passively with no moving parts or fans• Uses wired communication for fast and consistent connection• Updates software and rmware remotelySimple• Fully integrated AC battery system• Installs and commissions easily• Supports Backup, Self-Consumption, and time-of-use (TOU) modes• Oers homeowners remote monitoring and control from the Enphase App• Field replaceable componentsSafe• Evaluated to UL 9540A for large scale re testing and reduced separation distance as required in 2021 IRC R328.3.1, 2021 IFC 1207.1.5, and 2023 NFPA 855 15.3.1 and 9.1.5.1• Uses lithium iron phosphate (LFP) chemistry for maximum safety and longevityDATASHEETNADimensions in inchesFloor mounted with pedestal (sold separately)UL 9540ACertiedLISTED22.8"7.4"9.9"1.2"3.3"1 Follow all installation instructions and local codes and requirements of the Authority Having Jurisdiction (AHJ) when installing Enphase ESS.Wall mounted
© 2023 Enphase Energy. All rights reserved. Enphase, the e and CC logos, IQ, and certain other marks listed at https://enphase.com/trademark-usage-guidelines are trademarks of Enphase Energy, Inc. in the US and other countries. Data subject to change.IQB-5P-DSH-00010-4.0-EN-US-2023-11-07IQ Battery 5PMODEL NUMBERIQBATTERY-5P-1P-NAThe IQ Battery 5P system with integrated IQ Microinverters and battery management system (BMS) with battery controllerWHAT’S IN THE BOXIQ Battery 5P unit IQ Battery 5P unit (B05-T02-US00-1-3)ID cover and conduit cover IQ Battery 5P cover with two conduit covers for the left and right sides of the unitBottom mounting bracket and top shield Bottom mounting bracket for mounting the battery on the wall. One top shield is required for UL9540A M5 seismic screws Two M5 seismic screws for securing the battery unit on the bottom mounting bracketM4 grounding screws Two M4 grounding screws for securing the top shield on the bottom mounting bracketM5 ID cover grounding screws Two M5 ID cover grounding screws for the EMI/EMC requirementCable ties Six cable ties for securing eld cables to the unitControl (CTRL) connector Spare CTRL connector without resistor for CTRL wiringControl (CTRL) connector with resistor Spare CTRL connector with resistor for CTRL wiringQuick Install Guide (QIG) QIG for IQ Battery unit installation instructionsOPTIONAL ACCESSORIES AND REPLACEMENT PARTSIQ8D-BAT-RMA IQ8D-BAT Microinverter for eld replacementB05-T02-US00-1-3-RMA IQ Battery 5P Battery unit for eld replacementB05-CX-0550-O IQ Battery 5P cover for eld replacementB05-PI-0550-O IQ Battery 5P pedestal mountB05-CP-096-OIQ Battery 5P conduit plates for eld replacement. Includes one left-side and one right-side conduit plateB05-WB-0543-OIQ Battery 5P wall bracket for eld replacement. Includes one bottom mounting bracket and one top shieldIQBATTERY-HNDL-5 IQ Battery 5P lifting handles. Includes one left-side and one right-side lifting handleB05-ACFB-080-O IQ Battery 5P AC lter board for eld replacementB05-BMSNA-0490-O IQ Battery 5P BMS board for eld replacementB05-CANB-063-O IQ Battery 5P control communication board for eld replacementB05-NICS-0524-O, B05-NUCS-0524-O IQ Battery 5P control switch is preinstalled on the wiring cover for eld replacementOUTPUT (AC)@240 VAC2Rated (continuous) output power 3.84 kVAPeak output power 7.68 kVA (3 seconds), 6.14 kVA (10 seconds)Nominal voltage/range 240/211–264 VACNominal frequency/range 60/57–63 HzRated output current (@240 VAC) 16 APeak output current (@240 VAC) 32 A (3 seconds), 25.6 A (10 seconds)Power Start capability Up to 48 A LRA3Power factor (adjustable) 0.85 leading...0.85 laggingMaximum units per 20 A branch circuit One unit (single-phase)Maximum conductor size supported 3 AWGOvercurrent protection device (OCPD) for 3 AWG cable 80 AInterconnection Single-phaseAC round-trip eciency490%2 Supported in both grid-connected and backup/o-grid operation.3 Power Start capability may vary.4 AC to the battery to AC at 50% power rating.
© 2023 Enphase Energy. All rights reserved. Enphase, the e and CC logos, IQ, and certain other marks listed at https://enphase.com/trademark-usage-guidelines are trademarks of Enphase Energy, Inc. in the US and other countries. Data subject to change.IQB-5P-DSH-00010-4.0-EN-US-2023-11-07IQ Battery 5PBATTERYTotal capacity 5.0 kWhUsable capacity 5.0 kWhDC round-trip eciency 96%Nominal DC voltage 76.8 VMaximum DC voltage 86.4 VAmbient operating temperature range (charging) -20°C to 50°C (-4°F to 122°F) non-condensingAmbient operating temperature range (discharging) -20°C to 55°C (-4°F to 131°F) non-condensingOptimum operating temperature range 0°C to 30°C (32°F to 86°F)Chemistry Lithium iron phosphate (LFP)MECHANICAL DATADimensions (HxWxD) 980 mm x 550 mm x 188 mm (38.6 in x 21.7 in x 7.4 in)Lifting weight 66.3 kg (146.1 lbs)Total installed weight 78.9 kg (174 lbs)Enclosure Outdoor–NEMA 3RIQ8D-BAT Microinverter enclosure NEMA type 6Cooling Natural convectionAltitude Up to 2,500 meters (8,202 feet)Mounting Wall-mount or pedestal-mount (sold separately)FEATURES AND COMPLIANCECompatibilityCompatible with IQ and M Series Microinverters, IQ System Controller 3/3G, IQ Combiner 5/5C, and IQ Gateway for grid-tied and backup operationCommunication Wired control communicationServices Backup, Self-Consumption, TOU, and NEM integrityMonitoring Enphase Installer Platform and Enphase App monitoring options; API integrationComplianceCA Rule 21 (UL 1741-SA), IEEE 1547:2018 (UL 1741-SB, 3rd Ed.)CAN/CSA C22.2 No. 107.1-16UL 95405, UL 9540A, UN 38.3, UL 1998, UL 991, NEMA Type 3R, AC156EMI: 47 CFR, Part 15, Class B, ICES 003Cell module: UL 1973, UN 38.3Inverters: UL 62109-1, IEC 62109-2LIMITED WARRANTYLimited warranty >60% capacity, up to 15 years or 6,000 cycles65 Following local standards, choose a well-ventilated, non-habitable, indoor location (like a 2-car garage) or in an outdoor location, which is out of direct sunlight and where the ambient temperature and humidity are within -4°F to 113° F (-20°C to 45°C) and 5% to 95% RH, non-condensing. 6 Whichever occurs rst. Restrictions apply.
© 2023 Enphase Energy. All rights reserved. Enphase, the e and CC logos, IQ, and certain other marks listed at https://enphase.com/trademark-usage-guidelines are trademarks of Enphase Energy, Inc. in the US and other countries. Data subject to change.IQB-5P-DSH-00010-4.0-EN-US-2023-11-07Revision historyREVISION DATE DESCRIPTIONDSH-00010-4.0 November 2023 Updated the “Output (AC)” table.DSH-00010-3.0 September 2023• Updated product images.• Editorial updates.DSH-00010-2.0 July 2023• Added battery isometric view on the rst page.• Editorial updates.DSH-00010-1.0 May 2023 Initial release.