Return to flip book view

Q.PEAK DUO XL-G10.d 475-495

Page 1

Q PEAK DUO XL G10 d 475 495 ENDURING HIGH PERFORMANCE BREAKING THE 21 EFFICIENCY BARRIER Q ANTUM DUO Z Technology with zero gap cell layout boosts module efficiency up to 21 6 LOW ELECTRICITY GENERATION COSTS Higher yield per surface area lower BOS costs and up to 80 watts more module power than standard 144 half cell modules ENDURING HIGH PERFORMANCE Long term yield security with Anti LID Technology Anti PID Technology1 Hot Spot Protect and Traceable Quality Tra Q EXTREME WEATHER RATING High tech aluminium alloy frame certified for high snow 5400 Pa and wind loads 3000 Pa A RELIABLE INVESTMENT Inclusive 12 year product warranty and 25 year linear performance warranty2 STATE OF THE ART MODULE TECHNOLOGY Q ANTUM DUO combines cutting edge cell separation and innovative wiring with Q ANTUM Technology 1 2 THE IDEAL SOLUTION FOR Ground mounted solar power plants APT test conditions according to IEC TS 62804 1 2015 method A 1500 V 96 h See data sheet on rear for further information

Page 2

MECHANICAL SPECIFICATION Format 2216 mm 1045 mm 35 mm including frame Weight 26 0 kg Front Cover 3 2 mm thermally pre stressed glass with anti reflection technology AU EN Back Cover Composite film Frame Anodised aluminium Cell 6 26 monocrystalline Q ANTUM solar half cells Junction box 53 101 mm 32 60 mm 15 18 mm Protection class IP67 with bypass diodes Cable 4 mm Solar cable 700 mm 350 mm Connector St ubli MC4 Evo2 Hanwha Q CELLS HQC4 IP68 2216 mm 1308 mm 790 mm 454 mm 400 mm 4 Grounding holes 4 5 mm 4 Drainage holes 4 Mounting slots system Tracker DETAIL B Frame 700 mm 1003 mm 1001 mm 1045 mm 350 mm Label 8 Drainage holes 3 6 mm 4 Mounting slots DETAIL A 35 mm Long cables 1450 mm 1450 mm for landscape installation are available upon request DETAIL A 16 mm DETAIL B 8 5 mm 21 mm 10 mm 7 mm 22 mm Drawing not to scale ELECTRICAL CHARACTERISTICS 475 POWER CLASS 480 485 490 495 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS STC1 POWER TOLERANCE 5 W 0 W Minimum Power at MPP1 PMPP W 475 480 485 490 495 Short Circuit Current1 I SC A 11 24 11 26 11 29 11 31 11 34 Open Circuit Voltage1 VOC V 53 58 53 61 53 64 53 68 53 71 Current at MPP I MPP A 10 66 10 71 10 76 10 81 10 86 Voltage at MPP VMPP V 44 54 44 81 45 07 45 33 45 59 20 5 20 7 20 9 21 2 21 4 371 4 Efficiency1 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS NMOT2 Minimum Power at MPP W 356 4 360 1 363 9 367 6 I SC A 9 05 9 07 9 09 9 12 9 14 Open Circuit Voltage VOC V 50 53 50 56 50 59 50 62 50 65 Current at MPP I MPP A 8 39 8 43 8 47 8 52 8 56 Voltage at MPP VMPP V 42 49 42 72 42 94 43 17 43 39 Measurement tolerances PMPP 3 I SC VOC 5 at STC 1000 W m2 25 2 C AM 1 5 according to IEC 60904 3 2 800 W m NMOT spectrum AM 1 5 100 PERFORMANCE AT LOW IRRADIANCE At least 98 of nominal power during first year Thereafter max 0 5 degradation per year At least 93 5 of nominal power up to 10 years At least 86 of nominal power up to 25 years Q CELLS Industry standard for linear warranties 98 95 90 86 85 80 0 5 10 15 20 Standard terms of guarantee for the 10 PV companies with the highest production capacity in 2014 as at September 2014 25 All data within measurement tolerances Full warranties in accordance with the warranty terms of the Q CELLS sales organisation of your respective country YEARS 110 100 90 80 200 400 600 800 1000 IRRADIANCE W m Typical module performance under low irradiance conditions in comparison to STC conditions 25 C 1000 W m2 TEMPERATURE COEFFICIENTS Temperature Coefficient of I SC K 0 04 Temperature Coefficient of VOC Temperature Coefficient of PMPP K 0 34 Nominal Module Operating Temperature Maximum System Voltage VSYS V 1500 Maximum Reverse Current IR A 20 K 0 27 NMOT C 43 3 PROPERTIES FOR SYSTEM DESIGN Max Design Load Push Pull Pa 3600 2000 Max Test Load Push Pull Pa 5400 3000 QUALIFICATIONS AND CERTIFICATES IEC 61215 2016 IEC 61730 2016 This data sheet complies with DIN EN 50380 Certification in process PV module classification Class II Fire Rating based on ANSI UL 61730 C TYPE 1 Permitted Module Temperature on Continuous Duty 40 C 85 C PACKAGING INFORMATION 24t 40 HC Horizontal packaging 2270 mm 1100 mm 1210 mm 807 kg 22 pallets 20 pallets 29 modules Note Installation instructions must be followed See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product Hanwha Q CELLS GmbH Sonnenallee 17 21 06766 Bitterfeld Wolfen Germany TEL 49 0 3494 66 99 23444 FAX 49 0 3494 66 99 23000 EMAIL sales q cells com WEB www q cells com Specifications subject to technical changes Q CELLS Q PEAK DUO XL G10 d_475 495_2021 06_Rev02_EN EN RELATIVE EFFICIENCY COMPARED TO NOMINAL POWER Q CELLS PERFORMANCE WARRANTY RELATIVE EFFICIENCY 1 PMPP Short Circuit Current

Page 3

LIMITED WARRANTY FOR CRYSTALLINE PHOTOVOLTAIC MODULES FROM Q CELLS Document issued on February 1st 2021 This limited warranty Limited Warranty is issued by Hanwha Solutions Corporation 86 Cheonggyecheon ro Jung gu Seoul Republic of Korea 04541 or its successors or assigns HSC and applies exclusively to Q CELLS Modules as defined in Section 1 a 1 SCOPE 2 WARRANTY a Products Q CELLS Modules are defined in this Limited Warranty as Q CELLS branded photovoltaic modules manufactured by HSC or its authorized manufacturers that are sold and installed within the United States Canada Mexico Panama and Costa Rica and are of the following product type a Product Warranty Subject to the terms and conditions in this Limited Warranty HSC warrants to the Customer for a period of twenty five 25 years following the Warranty Start Date that the Q CELLS Modules when installed used and serviced under normal operating conditions and in accordance with Q CELLS Module Installation Manual provided by HSC or Distributor will be free from any defects in materials and workmanship that have a significantly negative effect on the power output of the Q CELLS Modules collectively Product Defect The Product Warranty does not warrant a specific power output of the Q CELLS Modules which shall be exclusively covered under the Performance Warranty in Section 2 b Product Defect does not include any cosmetic changes or other changes in the Q CELLS Modules appearance including but not limited to any color changes mold and normal wear and tear Q PEAK DUO G9 Q PEAK DUO BLK G9 Q PEAK DUO ML G9 Q PEAK DUO BLK ML G9 Q PEAK DUO ML G10 Q PEAK DUO BLK ML G10 Q PEAK DUO ML G10 a Q PEAK DUO BLK ML G10 a b Beneficiary The sole and exclusive beneficiary of this Limited Warranty is an end customer who purchases Q CELLS Modules from HSC or from any one of its authorized distributors Distributor and is the initial installer of such modules into a specific photovoltaic PV solar energy project Project and any of the end customer s permitted successors or assigns Customer c Term The term of this Limited Warranty Term for the Customer begins on the delivery date to the original Customer Warranty Start Date and ends at the end of the warranty periods set forth in Section 2 If the Customer is unable to provide sufficient and adequate documentation of the delivery date to the original Customer the Warranty start Date sixty 60 days after the following the Module s was manufactured as indicated by the serial number The performance of warranty services under this Limited Warranty does not extend the Term HSC s obligations under this Limited Warranty are conditioned upon the Customer s compliance with its payment obligations for purchase of the applicable Q CELLS Module b Performance Warranty Subject to the terms and conditions of this Limited Warranty HSC warrants to the Customer that the Q CELLS Modules are manufactured to i produce a power output of at least ninety eight percent 98 of the minimum power output specified in the applicable module data sheet during the first twelve 12 months following the Warranty Start Date and ii have a yearly maximum decrease or degradation of power of not more than fifty hundredths of one percent 0 5 from start of the second 2nd twelve 12 month period following the Warranty Start Date until the end of such twelve 12 month period and repeated for each successive twelve 12 month period until the twenty fifth 25th anniversary of the Warranty Start Date collectively Performance Warranty As an example the Q CELLS Module will be manufactured to have a minimum power output of eighty six percent 86 of the minimum power output specified in the applicable module data sheet at the end of the term of this Limited Warranty Failure to meet the Performance Warranty is defined herein as a Performance Defect In the event of a Performance Defect claim the power output of any Q CELLS Modules described in this Section 2 b shall be measured by HSC under the

Page 4

Standard Test Conditions STCs defined in the IEC standards EN 61215 and 60904 3 in effect as of the Warranty Start Date 8 Q CELLS Modules are modified or used in processes involving other products without obtaining the prior written consent of HSC 3 EXCLUSIONS The Limited Warranty shall not apply to any Q CELLS Modules affected by the following events or conditions 1 usage transport storage installation and or handling in any manner that fails to strictly comply with the Installation Manual and the Packaging and Transportation Information sheet provide upon request applicable to the Q CELLS Modules 2 system or components of such system that are of a design configuration or installation that does not meet the standards typically used by experienced professionals in the industry 3 incorrect improper or inadequate service operation or maintenance of the Q CELLS Modules or of the Project or any normal wear and tear of the Q CELLS Modules 4 damage caused by extreme environmental sources of impact including but not limited to i acid rain or snow ii blowing sand iii saline air iv pollution of any kind in the air soil or groundwater v unusual oxidation levels vi mold or vii any nearby fire explosion smoke or charring 5 damage caused by acts of nature or acts of God including but not limited to lightning hail frost snow storms tidal waves floods extreme temperatures earthquakes typhoons tornadoes volcanic eruptions meteorites ground motions earth fissures or landslides 6 damage caused directly or indirectly by acts of violence or intervention by third parties or external forces including but not limited to misadventure riots war insurrection communal violence unintentional damage by third parties vandalism damage caused by animals and or acts or omissions by third parties beyond the reasonable control of HSC 7 damage to the Project in which the Q CELLS Modules are installed caused by external factors including but not limited to voltage fluctuations power peaks excess current power failure poor electrical or mechanical engineering work or other faults occurring in a power supply system with or without mains connection whether or not such faults in the power supply system was contributed to by any act or omission of the Customer 9 the serial number or product label has been removed changed deleted or made unrecognizable 10 the Q CELLS Modules are used on any mobile carriers such as motor vehicles or ships 11 the conditions of use at the Project at any time exceed the specifications set out in the applicable module data sheet and or 12 the Customer fails to notify HSC of a Product Defect or Performance Defect within 30 days of the initial discovery or prior to the end of the applicable warranty period set forth in Section 2 4 WARRANTY CLAIMS a Customer Inspection The original Customer must inspect the Q CELLS Modules for visible defects and notify HSC of any defects within 30 days of the delivery of the Q CELLS Modules Inspection Period If Customer does not notify HSC of the visible defects within the Inspection Period such modules shall be deemed as being accepted by the Customer b Warranty Claims The Customer will be entitled to make claims under this Limited Warranty Warranty Claims only if the Customer has provided documented evidence sufficient to prove that the malfunctioning or non conformity of the Q CELLS Modules resulted exclusively from a Product Defect or Performance Defect covered by this Limited Warranty If the Warranty Claim is based on glass breakage then the Customer shall conduct a static load calculation on the substructure c Warranty Claim Compliance The Customer must comply with the HSC s current Return Merchandise Authorization RMA process available upon request to make any Warranty Claim HSC will not accept any Warranty Claims not in compliance with the RMA or Warranty Claims that use the delivery of any unauthorized return shipments of Q CELLS Modules d Warranty Claim Procedure The Customer is responsible for shipping the Q CELLS Modules to HSC for evaluation at the Customer s expense HSC shall pay the costs of a technical inspection and in the event that the warranty

Page 5

claim is confirmed by such inspection transportation Otherwise the Customer shall be charged with these costs To make a Warranty Claim the Customer must submit the original receipt or invoice which bears the date of the purchase and of the delivery the serial numbers of the relevant Q CELLS Modules and the name of the authorized distributor or seller tion depreciated purchase price per watt guaranteed power output actual power output provided however if the Customer fails to produce an original invoice then the price shall be based upon the then current per watt market price of a comparable PV module in a similar market and the date shall be based upon the date of manufacture according to the HSC records e Ownership Interest The Q CELLS Modules sent to HSC in the course of the RMA process shall remain the property of the Customer until any inspection has been completed and HSC provides a replacement or refund At the time any refund or delivery of a replacement Q CELLS Module to the Customer takes place under this Limited Warranty the ownership interest of the defective module passes to HSC Any repaired replaced or additionally supplied modules will be warranted only for the remainder of the original warranty period applicable to the original Q CELLS Modules c Discontinued products In the event the Module s is no longer available Q CELLS reserves the right to deliver replacement Module s that may differ in size color shape model number but with equivalent or higher power level 5 REMEDIES a Product Defect Remedy If HSC determines following a Warranty Claim that a Q CELLS Module has a Product Defect then HSC shall at its discretion within a reasonable time i remedy or repair the Product Defect ii provide a replacement module in place of the Q CELLS Module with the Product Defect or iii provide the Customer monetary compensation equal to the purchase price of the Q CELLS Module subject to an annual four percent 4 depreciation rate on the original purchase price as evidenced by the invoice produced by the Customer provided however if the Customer fails to produce an original invoice then the price shall be based upon the then current per watt market price of a comparable PV module in a similar market and the date shall be based upon the date of manufacture according to the HSC records b Performance Warranty Remedy If HSC determines following a Warranty Claim that a Q CELLS Module has a Performance Defect then HSC shall at its discretion within a reasonable time i remedy or repair the Performance Defect ii provide a replacement module in place of the Q CELLS Module that has the Performance Defect iii make up the difference to the guaranteed power output by providing additional modules or iv provide to the Customer monetary compensation that shall be calculated at the time of a justified Customer s Warranty Claim subject to Section 4 of this Limited Warranty and shall be the difference between the applicable guaranteed power output and actual power output measured by the STCs multiplied by the price per watt of the Q CELLS Module in which such price shall be calculated by applying an annual four percent 4 depreciation rate to the purchase price as evidenced by the original invoice provided by the Customer monetary compensa d Sole and Exclusive Remedy and Obligation THE REMEDIES SET FORTH IN THIS SECTION 5 ARE HSC S SOLE AND EXCLUSIVE LIABILITY AND OBLIGATION AND THE CUSTOMER S SOLE AND EXCLUSIVE REMEDIES FOR ANY PRODUCT DEFECT OR PERFORMANCE DEFECT IN ANY Q CELLS MODULE THE REMEDY EXTENDED TO THE CUSTOMER SPECIFICALLY EXCLUDES ANY REIMBURSEMENT FOR THE COSTS OR EXPENSES INCURRED IN THE DISMANTLING OR INSTALLATION OF THE Q CELLS MODULES REPLACEMENT MODULES OR PARTS OR LOSS OF POWER 6 WARRANTY LIMITATIONS THE WARRANTIES SET FORTH IN THIS LIMITED WARRANTY ARE IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS IMPLIED OR STATUTORY REGARDING ANY Q CELLS MODULES INCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR NON INFRINGEMENT HOWEVER IF A Q CELLS MODULE IS SOLD AS A CONSUMER PRODUCT TO THE EXTENT REQUIRED BY APPLICABLE LAW ANY IMPLIED WARRANTIES OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR NON INFRINGEMENT ARE LIMITED TO THE PERIODS OF THE LIMITED PRODUCT AND LIMITED PERFORMANCE WARRANTIES SET FORTH ABOVE OR SUCH SHORTER PERIOD AS REQUIRED BY APPLICABLE LAW THIS LIMITED WARRANTY GIVES THE CUSTOMER SPECIFIC LEGAL RIGHTS AND THE CUSTOMER MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE HSC IS NOT RESPONSIBLE OR LIABLE IN ANY WAY FOR DAMAGE OR INJURY TO PERSONS OR PROPERTY OR FOR OTHER LOSS OR INJURY RESULTING FROM ANY CAUSE WHATSOEVER ARISING OUT OF OR RELATED TO ANY Q CELLS MODULES UNLESS OTHERWISE STIPULATED BY MANDATORY STATUTORY LAW IN PARTICULAR HSC S LIABILITY FOR FRAUDULENT OR WILLFUL INTENT GROSS NEGLIGENCE OR PERSONAL INJURY IN EACH CASE UNDER APPLICABLE MANDATORY LIABILITY LAW SHALL REMAIN UNAFFECTED

Page 6

EXCEPT AS PROVIDED IN THIS SECTION 6 THE Q CELLS MODULES THE PRODUCT DOCUMENTATION AND ALL INFORMATION ARE PROVIDED ON AN AS IS BASIS and any attempt to assign or transfer in violation of this Section 7 shall be null and void 8 MISCELLANEOUS SOME JURISDICTIONS LIMIT OR DO NOT PERMIT DISCLAIMERS OF LIABILITY SO THIS PROVISION MAY NOT APPLY TO THE CUSTOMER IN SAID JURISDICTION SOME JURISDICTIONS DO NOT ALLOW LIMITATIONS OR THE EXCLUSION OF DAMAGES SO THE ABOVE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO THE CUSTOMER IN SAID JURISDICTION THE CUSTOMER MAY HAVE SPECIFIC LEGAL RIGHTS OUTSIDE THIS LIMITED WARRANTY FOR Q CELLS MODULES AND MAY ALSO HAVE OTHER MANDATORY RIGHTS THAT VARY FROM JURISDICTION TO JURISDICTION WHICH SHALL REMAIN UNAFFECTED IN NO EVENT WILL HSC BE LIABLE FOR ANY CONSEQUENTIAL INDIRECT EXEMPLARY SPECIAL OR INCIDENTAL DAMAGES INCLUDING LOSS OF USE LOST REVENUE AND OR LOST POWER ARISING FROM OR RELATING TO THIS WARRANTY OR ANY Q CELLS MODULE OR ANY REPLACEMENT OR ADDITIONAL MODULE SUPPLIED BY HSC HEREUNDER EVEN IF HSC IS AWARE OF THE POSSIBILITY OF SUCH DAMAGES THE TOTAL LIABILITY OF HSC ANY DISTRIBUTOR AND OR THEIR RESPECTIVE OFFICERS DIRECTORS EMPLOYEES AND AGENTS ARISING FROM OR RELATING TO THIS LIMITED WARRANTY WHETHER IN CONTRACT TORT OR OTHERWISE WILL NOT EXCEED THE AMOUNT RECEIVED BY HSC FOR THE Q CELLS MODULE THAT IS THE SUBJECT OF THE CLAIM OR DISPUTE SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO THE CUSTOMER IN SAID JURISDICTION a Survival If any provision of this Limited Warranty terms and conditions is held to be invalid illegal or unenforceable in any respect such provision will be changed and interpreted to accomplish the objectives of such provision to the greatest extent possible under applicable law and the remaining provisions will continue in full force and effect b Governing Law All matters arising from or relating to this Limited Warranty shall be governed by the laws of the State of California without regard to its choice of law rules The UN Convention on the International Sale of Goods shall not apply c Waiver of Jury Trial Jurisdiction Any dispute controversy or claim arising out of or relating to this Limited Warranty or any of its provisions or the breach termination interpretation enforcement or validity thereof including any dispute hereby is waived to the fullest extent permitted by applicable Law any right it may have to a trial by jury with respect to any litigation directly or indirectly arising out of under or in connection with this Limited Warranty Any dispute controversy or claim arising out of or relating to this Limited Warranty or any of its provisions or the breach termination interpretation enforcement or validity thereof including any dispute irrevocably is submitted to the jurisdiction of the courts of the State of California and the federal courts of the United States of America located in the State of California solely in respect of the interpretation and enforcement of the provisions of this Limited Warranty 7 ASSIGNMENT Customer Assignment Customer Assignment Customer may assign this Limited Warranty for any Q CELLS Module to a new owner of the entire photovoltaic system in which such module is originally installed provided that such system remains intact in its original place of installation This Limited Warranty may not otherwise be assigned or transferred Hanwha Q CELLS America Inc 400 Spectrum Center Drive Suite 1400 Irvine CA 92618 USA TEL 1 949 748 59 96 EMAIL claims us q cells com inquiry us q cells com WEB www q cells us Subject to modifications Q CELLS HSC Warranty_terms_modules_Q PEAK_DUO G9 G10 _series_2021 02_Rev01_NA THE CUSTOMER ACKNOWLEDGES THAT THE FOREGOING LIMITATIONS ON LIABILITY ARE AN ESSENTIAL ELEMENT OF THE RELEVANT SALES AGREEMENT BETWEEN THE PARTIES AND THAT IN THE ABSENCE OF SUCH LIMITATIONS THE PURCHASE PRICE OF THE Q CELLS MODULES WOULD BE SUBSTANTIALLY HIGHER

Page 7

Certificate C201085 03 02 Photovoltaic PV modules Product of company Q PEAK DUO G10 Q PEAK DUO G10 Q PEAK DUO G10 4 Q PEAK DUO BLK G10 Q PEAK DUO BLK G10 Q PEAK DUO BLK G10 4 Q PEAK DUO G10 a Q PEAK DUO G10 a Q PEAK DUO BLK G10 a Q PEAK DUO BLK G10 a Hanwha Q Cells OT Thalheim Sonnenallee 17 21 06766 Bitterfeld Wolfen GERMANY were tested in the testfield of TechnoLab GmbH Wohlrabedamm 13 13629 Berlin Germany as per IEC 61701 2020 08 Salt mist corrosion testing of photovoltaic PV modules Severity 6 Salt concentration 5 Note This certificate refers solely to specimens stipulated in the test report 2010085 01 01 Marco K mpfert 2021 10 14 12 51 07 02 00 Marco K mpfert Berlin 2021 10 14 FB 59 01